Manual No. A9-12?OWNER'S MANUALand Installation InstructionsSeries QP55-GAIR-COOLED RECREATIONAL VEHICLE GENERATORSModel No. 00862-1POWER SYSTEMS
ENGINE PROTECTIVE DEVICESAUTOMATIC LOW OIL PRESSURE SHUTDOWNThe engine is equipped with a normally closed (N.C.) oil pressure switch (Figure 4).
SPECIFICATIONSFUEL REQUIREMENTSThis generator is equipped with a gasoline fuel system as standard equipment. Specific installations may pr
MAINTENANCEThis section includes information about simple maintenance which includes the following tasks;• Checking the engine oil level.• Changi
ENGINE AIR CLEANERClean and re-oil the foam pre-cleaner every three months or every 25 hours of operation, whichever occurs first. Servi
BATTERYAll lead-acid storage batteries will discharge when not in use. Inspect the generator battery as follows:Once Weekly: Inspect battery posts
INSTALLATION SAFETY RULESDANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with article 551, N
GENERAL INSTALLATION INFORMATIONPURPOSE AND SCOPE OF MANUALThese Installation Instructions have been prepared especially for the purpose of
LOCATION AND SUPPORTGENERATOR LOCATIONThe most desirable location for the generator set is between the vehicle's main frame members
GENERATOR RESTRAINTUse four 3/8"-16 hardened steel bolts (Grade 5) to fasten the generator to the supporting frame or the support
COMPARTMENT SIZEPlan the compartment size carefully. Provide a minimum clearance of 1/2 inch on the front and top, 1 inch on thè
GENERAL SAFETY RULESTHE MANUFACTURER SUGGESTS THAT THESE "RULES” FOR SAFE OPERATION BEA COPIED AND POSTED IN POTENTIAL HAZARD AREAS OF THE RECREA
ACOUSTICSFor additional noise abatement the installer may wish to consider the following:• Using special sound insulating materials.• Construction o
COOLING AND VENTILATING AIRIt is absolutely essential that an adequate flow of air for cooling, ventilating and engine combustion be supplied to the
Figure 25 — Air Inlet Using DuctworkFigure 26 — Air Inlet in Vehicle SkirtCOMPENSATING FOR RESTRICTIONSSuch materials as screening, louvers, or
GASOLINE FUEL SYSTEMInstalling a gasoline fuel system (Figure 27) for recreational vehicle generator sets must comply with applicable codes,
EXHAUST SYSTEMThe generator exhaust system must be safely and properly installed. Only approved mufflers and other exhaust system parts
ELECTRICAL CONNECTIONSBe sure to read “Generator AC Connection System” on Page 14.The following general rules apply to electrical connections
• If you use metallic conduit, vapor seal the end of the conduit where it enters the junction box. Do this because flexible metallic conduit is not v
— 26 —
BATTERY INSTALLATIONRECOMMENDED BAHERYInstall a battery that meets the following requirements:• Battery must be a 12 volt, automotive type storage ba
IDENTIFICATION RECORD AND GENERATOR FEATURESPlease record the following information from the generator DATA DECAI- or information decal.1.Model Number
OPTIONAL ACCESSORIESA plug-in receptacle (Figure 33) is provided on the generator set, above the muffler enclosure. Use this receptacle to connect a
POST INSTALLATION TESTSThe air cooled generator set was factory tested and adjusted using gasoline as a fuel. You should not be requi
INSTALLATION CHECK LISTLOCATION AND SUPPORTELECTRICAL CONNECTIONS___1. The generator is properly located.___2. The generator is properly supported.___
coо"Пm>33mсл>оgsmZСЛOСЛ
TROUBLESHOOTINGPROBLEM POSSIBLE CAUSES REMEDYEngine won't crank. 1.Fuse is blown.1.Replace fuse.2. Loose corroded or detective battery cables.2.T
ELECTRICAL DATADrawing No. A6692 Rev. ALETQENDвсе - BAtTGRY CKARGC RECTirtCRCBl - CIRCUIT BREAXER. 30AСВг - CIRCUIT BREAKER, 20AСВЭ - CIRCUIT
ELECTRICAL DATADrawing No. A6692 Rev. A‘issvia.*’~*<uTt«L COMCCTIOH 9t cSV9€»35 —
EXPLODED VIEW — ENGINE ACCESSORIESDrawing No. kl22>5— 36 —
REPAIR PARTS — ENGINE ACCESSORIESDrawing No. A7235 ITEM PART NO. QTY.DESCRIPTION1A65321MANIFOLD, INTAKE291039 1GASKET. MANIFOLD/HEAD3 51753 1HHCS-M6-1
TABLE OF CONTENTSOPERATING INSTRUCTIONSGENERAL SAFETY RULES...inside coverIDENTIFICATION RECORD AND GENERATOR FEAT
EXPLODED VIEW — SHEET METALDrawing No. A7233COcs— 38 —
REPAIR PARTS — SHEET METALDrawing No. A7233ITEM PART NO.QTY. DESCRIPTION1A43231SCROLL, FLYWHEEL245756 9 SCREW. TAPTITE M6-1.0 x 10 LG3292892.5ft.FOAM
Drawing No. A9650EXPLODED VIEW — BASE AND PULLEYS 40 —
__________________ REPAIR PARTS — BASE AND PULLEYSDrawing No. A9650ITEM PART#. QTY. DESCRIPTION ITEM PART#. QTY. DESCRIPTION1A58551 BASE, MOUNTING 33
EXPLODED VIEW — ALTERNATOR AND CONTROL PANELDrawing No. A9649— 42 —
REPAIR PARTS — ALTERNATOR AND CONTROL PANELDrawing No. A9649ITEM PART#. QTY. DESCRIPTIONITEMPART#. QTY.DESCRIPTION175995 1 LOWER BEARING CARRIER 39 43
EXPLODED VIEW — ENGINE PARTSDrawing No. A7894— 44 —
REPAIR PARTS — GN410 ENGINEDrawing No. A7894ITEM PART#. QTY. DESCRIPTION ITEM PART#.QTY.DESCRIPTION1215331 PISTON RING SET33 A73081GOVERNOR SPOOL2 719
EXPLODED VIEW — ENCLOSUREDrawing No. A9648— 46 —
REPAIR PARTS — ENCLOSUREDrawing No. A9648ITEM PART NO. QTY.DESCRIPTION1A91311 PANEL, TOP COVER2A9127 1 LOUVERED BACK COVER3A91291 PANEL, ENGINE SIDE4
READ THIS MANUAL THOROUGHLYIf you don't understand any portion of this manual, contact Generac for a demonstration of actual start
CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air Resources Board (“CARB") and Generac
EMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (“ECS Warranty") for 1995 and Later Model Year Utility and Lawn and Garden Equip
Generac’s Three-Year Limited Warranty For Recreationai Vehicie GeneratorsGenerac warrants to the original owner and subsequent purchasers from the dat
GENERATOR FAMILIARIZATIONGENERATOR APPLICABILITYThese generators have been designed and manufactured for supplying electrical power tor r
OPERATING INSTRUCTIONSGENERATOR CONTROL PANELMounted on the generator control panel (Figure 2) are the following features:Figure 2 — Typical Control P
ENGINE EXHAUST GASBefore starting the generator engine, you should be sure there is no way for exhaust gases to enter the vehicle in
AOPERATING PRECAUTIONSNever operate the recreational vehicle generator set while the vehicle is parked over dry leaves, dry grass or any